18 - Technical Alarm
The technical alarm zone will perform as below:
1.
2.
3.
19 - Reset
The reset zone will perform as below:
1.
2.
3.
20 - Instant Without Reset
The instant report zone will perform as below:
1.
2.
3.
Zone in Area
Each zone is assigned to an area. This assignment influences the way how zones are indicated
on keypads. Refer to Zone Indication Keypad and Event Log, page 59
RF Zones
The AMAX panel 3000 / 4000 identifies RF zones by Zone RFID. AMAX Keypad programming
supports entering RFID automatically for Radion devices. When zone RFID is asked, press *
button for 3 second toggles between AUTO and MANUAL mode. When MANUAL is selected,
enter 9 – digit RFID using pin keys. When AUTO is selected, trigger RF device in order to enter
RFID automatically.
Hardwired Input Zones
On-board Inputs:
The AMAX panel provides onboard hard-wired inputs. An additional input is provided for the
enclosure tamper.
Bosch Sicherheitssysteme GmbH
Disarm:
–
Zone normal - no alarm / no report
–
Zone triggered - alarm / report
AWAY Arm:
–
Zone normal - no alarm / no report
–
Zone triggered - alarm / report
–
Zone triggered - during exit time - alarm / report
–
Zone triggered - during entry time - alarm / report
STAY Arm: same as AWAY arm performance.
–
A technical zone does not send a restore report until the zone is restored
Disarm:
–
Zone normal - no alarm / no report
–
Zone triggered – performs system reset / no report
AWAY Arm:
–
Zone normal - no alarm / no report
STAY Arm: same as AWAY arm performance
Disarm:
–
Zone normal - no alarm / no restore report
–
Zone triggered - no alarm / sends report
AWAY Arm:
–
Zone normal - no alarm / no restore report
–
Zone triggered - no alarm / sends report
–
Zone triggered - during exit time – no alarm / sends report
–
Zone triggered - during entry time – no alarm / sends report
STAY Arm: same as AWAY Arm performance