en | Installation
6.5

Prerequisites for Certification conform Installation

6.5.1

EN 50131-3 Grade 2, Environmental Class 2 - AMAX 2100 / 3000 / 4000

Certification Body
VDS Schadenverhütung
Amsterdamer Str.172
50735 Köln
www.vds.de
T he Panel com plies with the Following Standards:
EN 50131- 3
EN 50131- 6
EN 50136 - 2- 1
All Communicators must be connected to a central monitoring station.
Only the onboard Dialer and the Option Bus Communicators can be used for EN Alarm
Transmission.
2014.4 | 01 | F.01U.267.112
EN 50136 - 2- 3
The system / product must be placed inside the monitored area on a stable surface
Keypads must be mounted to the inner side of the monitored area
Once the system is tested and ready to use, enclosure door and accessory enclosures
must be secured with the provided screws
To realize EN conform Alarm Indication and Transmission, one of the following devices
must be used
Two supervised Warning devices (PO-1 PO-2 & PO+) and one ATS 2 Communicator
(onboard Dialer, B426, D4020 or DX4020G)
One self powered Warning Device and one ATS 2 Communicator (onboard Dialer,
B426, D4020 or DX4020G)
Two Communicators, one ATS 2 (onboard Dialer, B426, D4020 or DX4020G) and one
ATS 1 (onboard Dialer, B426, D4020 or DX4020G)
One ATS 3 Communicator (DX4020 or B426)
one 12V / 7AH or one 12V / 18Ah Battery must be connected to the System
maximum current for all components with a 7Ah Battery = 550mA
maximum current for all components with a 18Ah Battery = 1500mA (standby 12h,
recharge battery 80% in 72h) (PCB =l 00mA, IUI-AMAX Keypads = 31mA, DX2010 = 35mA,
DX3010 = 10mA, B426 = 100mA, DX4020G = 65mA, RF3227E = 30mA, RFRC-OPT = 30mA)
To realize EN conform Arming procedure, an indication of arm / disarm status must be
accessible from outside the monitored area (this indication can be time limited)
To realize EN conform Access to the Monitored Area, one of the following methods must
be used
Opening a door (to the entry / exit route) must start the entry procedure
Indication of arm / disarm Status