Bosch ICP-AMAX4-P1 Installation Manual page 48

Amax panel 4000; amax panel 4000 en
Hide thumbs Also See for ICP-AMAX4-P1:
Table of Contents

Advertisement

48
en | Settings
* AMAX 4000 zone 1 only
00 – Zone Not Used
If a zone is not used, program the zone type location to 0. An EOL resistor is not required if
this zone type is not used. This zone type never activates the sirens or the dialer.
01 - Instant
The instant zone will perform as below:
1.
2.
3.
02 - Interior Instant
The interior instant zone will perform as below:
1.
2.
3.
03 - Delay
The delay zone will perform as below:
2014.4 | 01 | F.01U.267.112
16
17
18
19
20
21
Disarm:
Zone normal - no alarm / no report
Zone triggered - no alarm / no report
AWAY Arm:
Zone normal - no alarm / no report
Zone triggered - alarm / report
(Zone triggered during exit time no alarm / no report)
(Zone triggered during entry time alarm / report is delayed for 30 second or entry
time is expired, when system is disarmed before, no report)
STAY Arm:
Zone normal - no alarm / no report
Zone triggered - alarm / report
(Zone triggered during exit time no alarm / no report)
(Zone triggered during entry time alarm / report is delayed for 30 second / entry time
is expired, when system is disarmed before, no report) When Zone is triggered, not
bypassed and system is forced to arm, a Zone fault report is sent.
When the system is disarmed and zone is not restored before, a Zone fault restore
report is sent.
Disarm:
same as the instant zone disarm status
AWAY Arm:
same as the instant zone AWAY arm status
STAY Arm:
This zone will be Ignored and performed as disarm. Refer to Keypad Indicators to see
how the zone is displayed during exit time
When zone is triggered, not bypassed and system is forced to arm, a zone fault
report is send
When system is disarmed and zone is not restored before, a zone fault restore report
is sent
Delay exit
Interior delay exit
Technical alarm
Reset
Instant without reset
Reserved