Figure 6.3: Connection of Battery
6.3

System Power Up

After the AMAX panel is powered up, set the date and time. Otherwise, the system prompts as
fault.
After the AMAX panel is powered up or reset, it resets to previous arming / disarming status.
To reduce false alarms caused by system power-up (or by power supply restoration after both
mains supply and AUX power supply fail), the AMAX panel is designed to not perform zone test
within one minute after power-up.
6.4

System Status Indicator

The AMAX panel indicates the system status by using the LED status indicator on the system
main board.
Slow flash of red on status indicator (repeating on and off with an interval of 1 second)
indicates normal system operation.
Bosch Sicherheitssysteme GmbH
BATTERY
_
+
AMAX 4000
BATT
_
+
Installation Guide
Installation | en
25
_
+
Battery
2014.4 | 01 | F.01U.267.112