Bosch ICP-AMAX4-P1 Installation Manual page 116

Amax panel 4000; amax panel 4000 en
Hide thumbs Also See for ICP-AMAX4-P1:
Table of Contents

Advertisement

116
en | Address Programming
Output
Mode
Output
Time
* AMAX 2100 Areas 1 – 2, zones 1 - 8
AMAX 3000 Areas 1 – 8, zones 1 - 32
AMAX 4000 Areas 1 – 16, zones 1 – 64
** When PO -1 or PO -2 is set to inverted, then for these outputs supervision is disabled
DX3010 Output Programming
This section is optional programming.
Module
DX3010 Module 1 (output 5 - 12)
DX3010 Module 2 (output 13 - 20)*
Table 9.2: DX3010 Address Settings
* AMAX 3000 / 4000
DX3010 1 Output Programming
Address 0542 - 0605
Output 5
Output event type
Output area / zone
Output mode
Output time
Output 6
Output event type
Output area / zone
Output mode
Output time
Output 7
Output event type
Output area / zone
2014.4 | 01 | F.01U.267.112
28
Bypassed zone
29
Ready to arm
30
Walktest
0
Continuous output
1
Pulse
2
Inverted**
000 -
0 - 999 seconds
999
Installation Guide
AMAX panel 4000 / AMAX panel 4000
0 = All areas 1 - 16 = Areas 1 - 16
Address
150
151
Address
0542 - 0543
0544 - 0545
0546
0547 - 0549
Address
0550 - 0551
0552 - 0553
0554
0555 - 0557
Address
0558 - 0559
Default
00
00
0
000
Default
00
00
0
000
Default
00
Bosch Sicherheitssysteme GmbH
EN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Icp-amax4-p2-enIcp-amax-p3-enAmax 4000Amax 4000en

Table of Contents