148
en | Troubleshooting
When the disassembly of DX2010 module 1, 2, 3, 4, 5, or 6 is detected, zone expansion
module 1, 2 tamper report will be sent. When the module resumes to normal operation, the
fault recovery report will be generated.
Fault conditions:
When the disassembly of DX2010 module 1, 2, 3, 4, 5, or 6 is detected, the AMAX panel will
consider the occurrence of zone extension module 1, 2, 3, 4, 5 or 6 tamper.
Recovery conditions:
When the module tamper recovers, tamper 1, 2, 3, 4, 5, or 6 will be recovered. Fault
monitoring:
When the DX2010 module 1, 2, 3, 4, 5, or 6 tamper is detected, the report will be sent to the
relevant path according to programming address 0124.
The fault indicator on the keypad flashes slowly.
When module 1, 2, 3, 4, 5, or 6 tamper is recovered, the report will be sent to the specified
path.
If currently there are not other faults, the fault indicator of the keypad will go off.
Zone Tamper DEOL
Condition:
Tamper contact is triggered (zone is programmed as dual end of line)
Restore:
Tamper contact is restored and tamper condition is reset.
Supervise:
1.
2.
3.
Zone type Tamper
Condition:
Tamper contact (direct connected to the zone) is triggered (zone type = tamper)
Restore:
Tamper contact is restored and tamper condition is reset.
Supervise:
1.
2.
3.
Keypad Lock out
Condition:
Invalid code is entered more number of times than allowed by the code retry attempts
(programmed in address 0499)
Restore:
Keypad lock out is reset when the keypad lockout time (3min) is expired and the fault is reset.
Supervise:
1.
2.
2014.4 | 01 | F.01U.267.112
Report the sensor tamper to configured destination on Address 124 when the Sensor
tamper is detected.
Slow flash FAULT indicator (refer the detailed description in chapter keypad indicators).
When the tamper condition is reset, send the restored report to the configured
destinations. The FAULT indicator is turned off when there is no other system fault.
Report the tamper condition to configured destination on Address 124 when the tamper
condition is detected.
Slow flash FAULT indicator (refer the detailed description in chapter keypad indicators).
When the tamper condition is reset, send the restored report to the configured
destinations. The FAULT indicator is turned off when there is no other system fault.
Report the keypad lock out to configured destination on address 124 when the keypad
lock out is detected.
Slow flash FAULT indicator (refer the detailed description in chapter keypad indicators).
Installation Guide
AMAX panel 4000 / AMAX panel 4000
Bosch Sicherheitssysteme GmbH
EN