en | Optional Modules and Peripheral Devices
Flash (stable flash)
Flash (3 flashes)
Off
Table 5.10: B426 System Status Indicator
For more information about indicators, see B426, page 17.
5.6

DX4020-G

5.6.1

General

The Conettix ITS-DX4020-G GPRS communication module allows IP communication via
commercial GPRS network. Transmission of alarm information via GPRS is the default for ITS-
DX4020-G. SMS or USB mode can be chosen for configuration. Remote programming and
control of the AMAX panel is supported.
Installation
1. Before installing ITS-DX4020-G, all power supplies of the AMAX panel should be
disconnected.
2. Insert SIM card.
3. Use the standard three-hole installation mode to install the ITS-DX4020-G in the enclosure
of the AMAX panel or another enclosure.
4. Connect the magnetic antenna to ITS-DX4020-G.
5.6.2

Address Setting

Set bus address to 134.
See also
5.6.3

Wiring

The connection of ITS-DX4020-G and the AMAX panel is divided into two modes: GPRS and
GSM.
AMAX 2100 / 3000
AMAX 4000
Figure 5.8: GPRS Mode in Support of IP
2014.4 | 01 | F.01U.267.112
DX4020-G, page 18
Normal Operation
Normal power supply, without communication
Power failure or other failure conditions
Installation Guide
AMAX panel 4000 / AMAX panel 4000
DX4020G