5 Centralised remote controls
PSC-A64GT

5.1.4.2 Main screen


Overall view
"Monitor 1 (All groups)"
Present Indication
To display the present indication
(all groups)
Monitor 1 (All Groups)
F-Level
F-Level
1-A
1-B
Group1A-01
Group1A-02
Group1B-01
Group1A-03
Group1A-04
Group1B-03
Group1A-05
Group1A-06
Group1B-05
Group1A-07
Group1A-08
Group1B-07
Group1A-09
Group1A-10
Group1B-09
Group1A-11
Group1A-12
Group1B-11
Group1A-13
Group1A-14
Group1B-13
Group1A-15
Group1A-16
Menu
"Menu" Button
To indicate the menu items
such as "Filter Sign Reset",
"Schedule Setting", etc.
*1) Only for the "Normal Mode" operation. In "Run/Stop Only" mode, the operation is switched to Run
"Monitor 2 (Block)"
Present Indication
To display the present indication
(groups in block)
Monitor 2 (Block)
F-Level
F-Level
All Groups
1-A
26
Group1A-01
Group1A-02
DRY LOW
DRY LOW
AUTO
24
Group1A-05
Group1A-06
DRY LOW
DRY LOW
AUTO
20
Group1A-09
Group1A-10
DRY LOW
DRY LOW
22
Group1A-13
Group1A-14
DRY LOW
DRY LOW
Menu
"Menu" Button
To indicate the menu items
such as "Filter Sign Reset",
"Schedule Setting", etc.
*2) Only for the "Normal Mode" operation. In "Run/Stop Only" mode, the operation is switched to Run
238
TCGB0106 rev.0 - 12/2014
Unit Condition
To indicate the unit condition such as
filter sign, demand, etc.
25/01/2010 (Mon) 10:20
F-Level
2
Buffet 1
Group1B-02
Group2-01
Group2-02
North Area
Buffet 1
Group1B-04
Group2-03
Group2-04
East Area
Buffet 2
Group1B-06
Group2-05
Group2-06
North Area
Buffet 2
Group1B-08
Group2-07
Group2-08
East Area
Meeting
Group1B-10
Group2-09
Group2-10
Room A
Meeting
Group1B-12
Group2-11
Room C
Meeting
Room E
All Groups
All Groups
Alarm Info.
Setting
"Alarm Info." Button
To indicate the abnormality Tap
the button for details.
Unit Condition
To indicate the unit condition such as
filter sign, demand, etc.
25/01/2010 (Mon) 10:20
F-Level
Annex
1-B
2
26
20
Group1A-03
DRY LOW
AUTO
24
26
Group1A-07
DRY LOW
20
26
Group1A-11
DRY LOW
20
19
Group1A-15
DRY LOW
Setting by
Alarm Info.
Block
"Alarm Info." Button
To indicate the abnormality.
Tap the button for details.
Block Button
To change the screen display into "Block" Monitor
2 (Block) indication by tapping this button.
Group Button
To indicate the operating condition of each group
Annex
as follows:
Buffet 1
Green:
South Area
Gray: Stop
Buffet 1
West Area
Red:
Buffet 2
If the target group button is tapped, "Settings" of
South Area
the target group screen will be indicated. *1) (Refer
Buffet 2
to Run/Stop for each group section)
West Area
Meeting
Room B
"All Groups Stop" Button
Meeting
Room D
To stop all the units simultaneously which are con-
trolled by the central station.
Kiosk
"All Groups Run" Button
All Groups
Run
Stop
To run all the units simultaneously which are con-
trolled by the central station.
"All Groups Setting" Button
To change the setting of the units simultaneously
which are controlled by the central station.
Block Tab
To change the monitor display into "Block" or "All
Groups" indication.
Group Button
To indicate the operating condition
Green:
25
Gray: Stop
Group1A-04
Red:
DRY LOW
If the target group button is tapped, "Settings" of
26
the target group screen will be indicated. *2) (Refer
Group1A-08
to Run/Stop for each group)
DRY LOW
"Stop by Block" Button
23
Group1A-12
To stop the all groups operation in the target block
DRY LOW
simultaneously
AUTO
22
Group1A-16
"Run by Block" Button
DRY LOW
To run the all groups operation in the target block
Run by
Stop by
simultaneously
Block
Block
"Setting by Block" Button
To change the setting of the all groups in the
target block simultaneously.
Run
Abnormal
Stop.
Run
Abnormal
Stop.