When working with a text codepad, go to Menu 831 [Test adapter] to test the DLA.
5.1.3

Command 960 - Save and exit from Installer's Programming Mode

This command saves and exits from Installer's Programming Mode. You can exit from
Installer's Programming Mode from any location.
To exit from Installer's Programming Mode:
Enter [9 6 0 #]. The system returns to the disarmed state. When using the codepad, the STAY
and AWAY indicators are extinguished.
5.1.4

Command 961 - Reset the Control Panel to Factory Default Settings

This command resets the control panel to factory default values. You can reset the control
panel from any location.
To reset the control panel to factory defaults:
1.
2.
When working with a text codepad, go to Menu 138 [Factory default] to reset the system to
factory default settings.
5.1.5

Command 962 - Copy the Control Panel Memory to IUI-SOL-ADAPTER

This command copies the control panel memory to the direct link adapter. You can only use
the IUI-SOL-ADAPTER Direct Link Adapter with the control panel.
To copy the control panel memory to the direct link adapter:
1.
2.
3.
4.
5.
2017.10 | 03 | F.01U.298.026
Connect the direct link adapter to the Bosch SDI2 Bus pins at the bottom of the control
panel printed circuit board.
Enter [9 5 9 #]. Two beeps sound after a successful test of the direct link adapter. A long
beep indicates that the direct link adapter data is corrupt and must be erased to clear the
corrupt data.
Enter [9 6 0 #] to exit from Installer's Programming Mode. The STAY and AWAY indicators
are extinguished on the codepad and the system returns to the disarmed remote state.
Remove the direct link adapter from the control panel. Failure to exit from Installer's
Programming Mode before removing the direct link adapter can corrupt the data in the
direct link adapter.
Enter the Installer Code (the default is 1234) and press [#] to enter Installer's
Programming Mode. Two beeps sound and the STAY and AWAY indicators flash on the
codepad to indicate that you entered Installer's Programming Mode. The codepad
displays the data stored in Location 000.
Enter [9 6 1 #]. Two beeps sound and the system is reset to the factory default values.
Enter the Installer Code (the default is 1234) and press [#] to enter Installer's
Programming Mode. Two beeps sound and the STAY and AWAY indicators flash on the
codepad to indicate you entered Installer's Programming Mode. The codepad displays the
data stored in Location 000.
Connect the direct link adapter to the Bosch SDI2 Bus pins at the bottom of the control
panel printed circuit board.
Enter [9 6 2 #].Two beeps sound after the control panel memory is successfully copied to
the direct link adapter. A long beep indicates that the direct link adapter is corrupt and
must be erased to clear the corrupt data.
Enter command [9 6 0 #] to exit from Installer's Programming Mode. The STAY and AWAY
indicators are extinguished on the codepad to indicate the system is disarmed.
Remove the direct link adapter from the control panel. Failure to exit from Installer's
Programming Mode before removing the direct link adapter can corrupt the direct link
adapter.