en | Programmable Outputs
This one-shot polarity is normally 0 V and switches to open circuit when the event occurs.
Because the output switches back to 0 V when the one-shot time expires, the event returns to
normal, or the system is disarmed, the one-shot timer can be shortened regardless of the time
setting.
14 – Normally Low, Latching Open
This polarity is normally 0 V and switches to open circuit when the event occurs. The output
switches back to 0 V when the user holds down [7] on the remote codepad until two beeps
sound. Time parameters do not apply to this polarity.
16.5

Output Timing

The timing of outputs is calculated by the time base and a multiplier. These two values play
different roles depending on the selected polarity. When you program outputs to pulse, you
can set both the On and Off times. You can program one-shot polarities to operate from 200
ms to 99 hours.
Notice!
The maximum value you can program in the two multiplier locations is 9,9.
The multiplier value is a two-digit decimal number from 00 to 99. For greater accuracy, use 60
sec for 1-min intervals and 60 min for 1-hour intervals.
16.6

Pulsing Polarities

When programming pulsing polarities, you must set both the On and Off times. The duration,
or On time, for an output is determined by time base. In other words, there are only four
possible On times.
The Off time is calculated by multiplying the On time by a decimal number between 00 and 99.
If you want an output to operate for 200 ms every 5 sec, program the time settings as:
On Time: 1
Off Time: 2 5
On Time
200 ms
1 sec
1 min
1 hour
Table 16.3: Pulsing Time Settings
16.7

One-Shot Polarities

The duration, or On time, of an output is determined by the product of the time base and the
multiplier.
If you want an output to operate for 5 sec, program the time settings as:
Time Base: 2
Multiplier: 0 5
The On time is calculated by multiplying the time base setting (1 sec) by the multiplier value
(05) (for example, 1 x 05 = 5 sec).
2017.10 | 03 | F.01U.298.026
Off Time
200 ms to 19.8 sec
1 to 99 sec
1 to 99 min
1 to 99 hr
Installation Guide
Increments
200 ms
1 sec
1 min
1 hr
Control Panel
Tolerance
±200 ms
±1 sec
±1 min
± 1 hr