Control Panel
*Pulsing Mode
When you program the output polarity as pulsing, the time base becomes the ON time and the
multiplier becomes the OFF time. The OFF time is the time base x the multiplier. (For
example, if you want the output to pulse 1 sec. ON and 5 sec. OFF, you would program time
base as 2 and the multiplier as 05.)
Notice!
When event code Remote control 1 – 20 is selected, polarity mode shall be programmed as
time-independent option (including 1 = Normally open, going low, or 7, or 8, and 14).
16.2

B228 Output Mode

2 additional outputs are added when B228 is connected to Solution 3000.
0 - Not used
The B228 outputs are not used.
1 - Aux power
The B228 output is a +12V auxiliary power supply.
2 - Switched negative
4 - Open collector
When Option 2 or Option 4 is selected, the B228 output operates as onboard output. When
the B228 output is programmed for Remote Control Output 21 or 22, you can turn the remote
output on or off using the Master Code command [2580][5][AWAY].
16.3

Output Event Types

There are approximately 89 Output Event Types. Two numbers designate each Output Event
Type. Program these numbers into the appropriate locations for the output.
Notice!
All reset times reference Polarity 1 and 8. Reset times vary depending on the selected
polarity.
0,1 System Armed
This output operates when the system is armed. The output is reset when the system is
disarmed. If the system is partitioned, this output operates when both areas are armed in
AWAY Mode, STAY Mode 1 or STAY Mode 2.
0,2 System Disarmed
This output operates when the system is disarmed. The output is reset when the system is
armed. If the system is partitioned, this output operates when both areas are disarmed.
0,3 Armed in STAY Mode
This output operates when the system is armed in STAY Mode 1 or STAY Mode 2. The output is
reset when the system is disarmed. If the system is partitioned, this output operates when
either area is armed in STAY Mode 1 or STAY Mode 2.
0,4 Armed in AWAY Mode
This output operates when the system is armed in AWAY Mode. The output is reset when the
system is disarmed. If the system is partitioned, this output operates when either area is
armed in AWAY Mode.
0,5 Auto Arm Pre-Arming Alert Time
Bosch Security Systems, Inc.
Installation Guide
Programmable Outputs | en
2017.10 | 03 | F.01U.298.026
123