en | Programmable Outputs
If Area 1 is armed in AWAY Mode or STAY Mode1 or STAY Mode 2, Output Event Type 5,6
operates. The output is reset when Area 1 is disarmed.
5,10 Area 1 Is Disarmed
5,11 Area 2 Is Disarmed
These two outputs operate when their corresponding area is disarmed. The output is reset
when the corresponding area is armed.
Example
If Area 1 is disarmed, Output Event Type 5,10 operates. The output is reset when Area 1 is
disarmed.
5,14 Any Areas Armed
This output operates when either Area 1 or Area 2 is armed in AWAY Mode or STAY Mode 1.
The output is reset when both areas are disarmed.
5,15 Any Areas Disarmed
This output operates when either Area 1 or Area 2 is disarmed. The output is reset when both
areas are armed in AWAY Mode or STAY Mode 1 or STAY Mode 2.
6,2 Remote Control 4
6,3 Remote Control 5
6,4 Remote Control 6
6,5 Remote Control 7
6,6 Remote Control 8
6,7 Remote Control 9
6,8 Remote Control 10
6,9 Remote Control 11
6,10 Remote Control 12
6,11 Remote Control 13
6,12 Remote Control 14
6,13 Remote Control 15
6,14 Remote Control 16
6,15 Remote Control 17
7,0 Remote Control 18
7,1 Remote Control 19
7,2 Remote Control 20
7,3 Remote Control 21
7,4 Remote Control 22
These outputs operate output when using the master code function or A-Link software or
Smartphone App (RSC) to turn remote output on. The output is reset when using the master
code function or A-Link software or Smartphone App (RSC) to manually turn remote output off
or automatically turn remote output 3 off when the ON time expires if output polarity is from 3
to 6 or from 10 to 13.
16.4

Output Polarity

There are fifteen different polarities. Each polarity is designated by a number that you program
into the appropriate location for the output.
0 – Output Not Used
If an output is not required, program the polarity as 0.
1 – Normally Open, Going Low
This polarity is normally open circuit and switches to 0 V when the event occurs. The output
switches back to open circuit when the event is restored. Time parameters do not apply to
this polarity.
2 – Normally Open, Pulsing Low
2017.10 | 03 | F.01U.298.026
Installation Guide
Control Panel
Bosch Security Systems, Inc.