Disable Factory Defaults - Bosch Solution 2000 Installation Manual

Hide thumbs Also See for Solution 2000:
Table of Contents

Advertisement

Control Panel
2.
3.
4.
5.
When working with a text codepad, go to Menu 137 [Version display] to check the control
panel firmware version.
5.2

Disable Factory Defaults

This feature prevents the control panel from manually restoring the default settings by the
default button and prevents the use of a programming key to automatically download to the
control panel when the system is disarmed.
Item
Button Default Options 0900
Enter the default setting of 0 for Location 900 to restore the control panel to its default
settings. Enter 15 for Location 900 to restrict the ability to restore the control panel to its
default settings and to require the Installer Code for future control panel programming.
If the Installer Code is unknown, you must restore the control panel to your Bosch distributor
for exchange. A nominal fee applies for this service.
Notice!
The use of this feature is not recommended.
If you are required to disable the ability restore the control panel to its default settings, a
special procedure eliminates the possibility of accidentally setting this option. You must hold
down the default button on the printed circuit board (PCB) when programming this location.
To prevent manually restoring the default control panel settings:
1.
2.
3.
4.
5.
6.
If Location 900 is not programmed as 15, do one of the following procedures to restore the
default control panel settings.
Bosch Security Systems, Inc.
Enter [9 9 9 #]. If you are using the codepad, the codepad lights a zone indicator
corresponding to the first digit of the version number.
Press [*]. The codepad lights a zone indicator corresponding to the second digit of the
version number.
Press [*] again to display the last digit. If the digit is 0, no zone indicator displays.
(Example: version 1.1.0, in location from 999 to 997 shows as 110.)
Enter [9 6 0 #] to exit from Installer's Programming Mode. The system returns to the
disarmed state. If you are using the codepad, the STAY and AWAY indicators are
extinguished to indicate the system is disarmed.
Location
Option
0 = Button Factory Default Enable
15 = Button Factory Default Disabled
Enter the Installer Code (the default is 1234) and press [#] to enter Installer's
Programming Mode. Two beeps sound and the codepad displays the data programmed in
Location 000. If you are using the codepad, the STAY and AWAY indicators flash to
indicate you entered Installer's Programming Mode.
Enter [9 0 0 #] to move to Location 900.
Press and hold the DEFAULT button.
Enter [1 5 *] to program 15 into Location 900.
Release the DEFAULT button.
Enter [9 6 0 #] to exit from Installer's Programming Mode. The system returns to the
disarmed state. If you are using a codepad, the STAY and AWAY indicators are
extinguished to indicate that the system is disarmed.
Installation Guide
Configuration | en
Default
New
0
2017.10 | 03 | F.01U.298.026
29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Solution 3000

Table of Contents