7.2

Master Code Functions

Master Code functions allow those users that have the appropriate priority level to perform
certain supervisory level functions. You can use these functions only when the system is
disarmed.
Notice!
The default Master Code (User Code 1) is 2580. It is possible to program multiple Master
Codes. Refer to User Code Priority, page 89 for more information.
To access a Master Code function, enter the Master Code and press the corresponding
function digit and the [AWAY] button. Except the Master Code functions listed in the table
below, Master Code functions also allows the users to arm or disarm single area.
Function
0
1
2
3
4
5
6
7
8
9989
Table 7.3: Master Code Functions
7.2.1

Arm or Disarm both Areas at the Same Time

This Master Code function only operates with partitioned control panel systems and allows
Master Codes allocated to both Area 1 and Area 2 to arm or disarm both areas at the same
time.
This feature allows a Master Code holder to arm or disarm the system by pressing one extra
button rather than entering a code twice. You can use any area codepad by a User Code
assigned to both areas with this function. To enable this feature, select Option 2 in Location
501 (refer to Partitioning Options 2, page 144).
To arm or disarm both areas at the same time:
Enter your Master Code and press [0][AWAY]. Two beeps sound and both areas are armed or
disarmed from AWAY Mode.
7.2.2

Arm or Disarm Single Area

This Master Code function allows to arm or disarm single area with any codepad.
Bosch Security Systems, Inc.
Description
Arm or disarm both areas at the same time
Add, change and delete user codes / remote radio user codes (RF keyfobs)
Change domestic phone numbers
Change Telco arm/disarm sequence
Set bypass zones for STAY Mode 2
Turn outputs on and off
Set the date and time
Walk test mode
Event memory recall mode
System reset