Communication Options
1
1 – Reporting Functions Allowed
When selected, this option operates for all reporting functions.
If you do not select this option, the communication does not operate.
Upload/Download using the A-Link-Plus software and telephone remote arming remains
operational regardless of this setting.
2 – Remote Arming by Telephone Allowed
If you select this option, you can remotely arm the system using a standard telephone by
pressing [*] on your touch-tone telephone.
Forced arming is automatically assumed when this feature is used.
4 – Answering Machine Bypass Only When Armed
Select this option to enable the Answering Machine Bypass feature when the system is armed.
When the system is disarmed, the control panel does not answer any incoming calls. This
option is beneficial in high telephone traffic installations where the control panel could
answer an incoming call.
8 – Use Bell 103 for FSK Format (Disabled=CCITT V21)
If this option is selected, the control panel uses the BELL 103 transmission frequency at 300
baud. If this option is not selected, the control panel uses the CCITT V21 transmission
frequency at 300 baud.
11.18
Communication Options 2
Item
Communication Options
2
1 – Arm/Disarm Reports Only if Previous Alarm
When selected, an Disarm Report is transmitted to the base station receiver when the system
is disarmed after an alarm occurred. When the system is armed, an Arming Report is
transmitted. An Arm or Disarm Report does not report again until the system registers another
alarm.
For a partitioned control panel, an Arm/Disarm Report is sent only for the area in which the
alarm occurred.
Bosch Security Systems, Inc.
Location
Option
0177
1 = Reporting functions allowed
2 = Remote arming by telephone allowed
4 = Answering machine bypass only when
armed
8 = Use Bell 103 for FSK format (Disabled
= CCITT V21)
Location
Option
0178
1 = Arm/Disarm Reports only if alarmed
2 = STAY Mode Arm/Disarm Reports
Enable
4 = Delay siren until transmission
complete
8 = Extend handshake wait time from 30
to 60 sec.
Installation Guide
Communication Information | en
Default
New
9
Default
New
0