en | Communication Information
automatically hangs up after the transmission sequence is repeated 10 times. If more than one
control panel dials to the same telephone number, the identification beep allows the customer
to verify the control panel that called.
The identification beep is programmed in Location 039/079/1456/1496 of the Subscriber ID
Number for Receiver 1/2/3/4.
Notice!
When set up for Domestic Dialing Format, the control panel attempts a maximum of six calls
for each alarm event (3 on the primary number and 3 on the secondary number of a receiver).
This count includes any unsuccessful calls. The counter is reset if the zone is reactivated and
the control panel attempts an additional six calls. The control panel stops dialing after an any
successful call. The control panel also stops dialing if a valid User Code is entered at the
codepad. If both Receiver 1 and Receiver 2 are programmed for domestic dialing, the
maximum number of calls for each alarm event is twelve.
To acknowledge domestic dialing:
If the received call is not acknowledged during any of the transmission pauses by pressing the
[*] button on a touch-tone telephone, the control panel repeats its transmission sequence 10
times and then it hangs up. If the call is successfully acknowledged during 10 times, the
control panel hangs up and makes no more calls for that event.
11.21.2

Setting Up and Programming Domestic Reporting

Programming the control panel for domestic reporting is extremely simple when using the
Installer's Programming Command 965.
To set up the control panel for domestic dialing:
1.
2.
3.
4.
5.
6.
7.
2017.10 | 03 | F.01U.298.026
Enter the Installer Code and press [AWAY] to enter Installer's Programming Mode. Two
beeps sound and the STAY and AWAY indicators flash.
Enter [9 6 5] and press [AWAY]. Two beeps sound. The control panel is now set up for
Domestic Dialing Format for Receiver 1.
Enter [9 6 0] and press [AWAY] to exit from Installer's Programming Mode. Two beeps
sound and the STAY and AWAY indicators are extinguished. The system returns to the
disarmed state.
Or skipping steps 1 - 3, with a text codepad, enter the installer code and press [AWAY] to
enter Installer's Programming Mode, go to menu 747 Set Up Domestic Dialing Format,
then exit with saving.
To program your telephone numbers, enter your Master Code and press [2][AWAY]. Three
beeps sound and the STAY and AWAY indicators flash. There are 4 telephone number
locations. Numbers 1 and 2 are for receiver 1. Numbers 3 and 4 are for receiver 2. After
the [965] command, the receiver 1 format is domestic and receiver 2 format is contact ID.
Press [1] to view and set/modify telephone number 1 followed by [AWAY] to complete
the process. If you still want to set telephone number 2, you will have to enter Master
Code and press [2][AWAY], then press [2] to select number 2. If any telephone numbers
are already programmed, they are displayed one digit at a time using the codepad
indicators. If no telephone numbers are programmed, two additional beeps sound after
you enter this mode. These two beeps normally sound after the last digit of the last
phone number is displayed.
Enter the digits for telephone number 1, one digit at a time. As you enter each digit, the
corresponding codepad indicator lights. If using a text codepad, the programmed number
and new entered number are displayed.
After the last digit of the telephone number, press [AWAY] to exit from this mode.