Control Panel
4.
Example
If Output 2 is programmed as 2,9,1,0,0,0 in Locations 442 to 447, the Master Code holder can
turn off this output by entering:
[2 5 8 0 5][AWAY][2][STAY][AWAY]
7.2.10

Setting the Date and Time

Use this function when the date and time must be changed or if the system was powered
down.
If the date and time is not set, the date and time fault appears only when the Auto Arming
Time is programmed in Locations 482 to 485 ( refer to Auto Arming Time, page 137), or when
you enter Fault Analysis Mode by holding down [5].
To set the new date and time:
1.
2.
Use 24:00 hour format when programming the hour of the day. Two beeps sound and the
STAY and AWAY indicators are extinguished. If a long beep sounds, an error occurred when
you entered the date and time.
Example
To set the date and time for 1st January 2014 at 10:30 PM, enter:
[2 5 8 0 6][AWAY][0 1 0 1 1 4 2 2 3 0][AWAY]
7.2.11

Walk Test Mode

See also
7.2.12

Event Memory Recall Mode

See also
7.2.13

System reset

Use this Master Code Function to reset the system manually.
To reset the system:
Enter your Master Code and press [9][9][8][9][AWAY]. Two beeps sound and the system is
reset.
If the control panel powers up after it is powered down, the system resets automatically.
7.3

User Code Functions

See also
7.3.1

Arm or Disarm both Areas at the Same Time

This User Code function operates only with partitioned systems and allows User Codes
allocated to both Area 1 and Area 2 to arm or disarm both areas at the same time.
Bosch Security Systems, Inc.
Press [AWAY] button to exit from this function. Two beeps sound and the STAY and AWAY
indicators are extinguished.
Enter your Master Code and press [6][AWAY]. Three beeps sound and the STAY and
AWAY indicators flash.
Enter the day, month, year, hour, and minute in DD, MM, YY, HH, MM format (where DD is
the day of the month, MM is the month of the year, YY is the year, HH is the hour of the
day, and MM is the minute of the day) and press [AWAY].
Walk Test Mode, page 49
Event Memory Recall Mode, page 49
Partitioning, page 144