"Assigning a Region to a Region Selection Button in the Numeric Keypad
Control Block" in Chpater 19 (Volume 3).)
It is not possible to select [MASTR] and other regions simultaneously. If
selected simultaneously, the master snapshot takes precedence.
The first pressed button lights green as the reference region, and
subsequently pressed buttons light amber.
Pressing one of the amber-lit buttons, while holding down [SNAPSHOT],
turns the button green to indicate its corresponding region as the new
reference region.
For details of the precedence order for becoming the reference region, see
"Reference region" (page 702).
The display shows the name of the reference region and the number of the
register previously recalled for that region.
3
Enter the desired register number from the numeric keypad.
See step 5 (page 789) in "Saving a snapshot from the numeric keypad
control block."
The entered register number appears in the display.
4
To apply temporary attributes, press the following buttons, turning them
on.
Control block
Cross-point control
block
Numeric keypad
control block
a) When Xpt Hold mode is selected in setup.
b) When Key Disable mode is selected in setup.
For the setup setting, see "Settings Relating to Keys, Wipes, Frame
Memory and Color Correction (Key/Wipe/FM/CCR Menu)" in Chapter 20
(Volume 3).
For details of temporary attributes and available attributes, see "Snapshot
Attributes" (page 785).
Temporary
Button
attribute to apply
A/B bus cross-point
[XPT HOLD] button in the
hold
background A/B bus
Key cross-point hold [XPT HOLD] button in the key bus
Key disable
[XPT HOLD] button in the key bus
Effect dissolve
[+/–/EFF DISS] button
Auto transition
[CLR/AUTO TRANS] button
Snapshot Operations From the Numeric Keypad Control Block
a)
b)
791