Basic Bridge Filter
Selection
Setting the
Advanced Bridge
Filter Status
Setting the
Advanced SRC
Address Filter Value
66
SD Series Ref. Manual (Packet & Transparent Mode)
2. Press the spacebar until the desired selection is displayed (
or
). Press
OFF
Bridge is ON
The purpose of this filter is to minimize the amount of Ethernet traffic
between the Polling radio and the Remote radios for more efficient oper-
ation. For example, Unicast and ARP allows pings as well as UDP and
TCP polling in the transceiver's bridge, but it does not allow some pro-
tocols that tend to flood a network, including Spanning Tree Protocol
(STP).
To set the Basic Bridge Filter Selection, proceed as follows:
1. Select
Basic Bridge Filter Sel
in the field to the right of the item.
2. Press the spacebar until the desired selection is displayed. Available
selections are:
Broadcast/Unicast (All), Unicast and ARP,
Press
to apply the change.
ENTER
The purpose of this filter is to only bridge the Ethernet traffic received
from a specific Ethernet-enabled device.
To set the Advanced Bridge Filter Status, follow these steps:
1. Select
Adv Bridge Filter Status
appears in the field to the right of the item.
2. Press the spacebar until the desired selection is displayed. Available
selections are:
Adv Src Addr Filter is OFF,
Press
to apply the change.
ENTER
To set the Advanced SRC Address Filter Value, follow the steps given
below:
1. Select
Adv Src Addr Filter Val
item clears and a flashing cursor appears.
2. Enter the desired filter value, and press
The entry format must be

IP Payload Configuration Settings

This section describes how to setup and configure the radio for
exchanging IP/Ethernet Payload data with Remote radios. It is an effi-
cient feature that supports Ethernet connectivity with maximum
over-the-air (OTA) efficiency for UDP and TCP data streams. Remote
radios receiving the data can then forward this traffic to their serial ports
or the Ethernet port. This feature is particularly useful for adding
Ethernet devices to a mixed SD/x710 system. This feature is distinctly
different than Ethernet Bridging, which is described above.
to apply the change.
ENTER
from the menu. A flashing cursor appears
from the menu. A flashing cursor
or
Adv Src Addr Filter is ON
on the menu. The field to the right of the
to apply the change.
ENTER
.
xx:xx:xx:xx:xx:xx
MDS 05-4846A01, Rev. C
Bridge is
and
.
Unicast Only
.