SERIAL I/O INTERFACE

SIO CONTROL REGISTERS (SIOCON)

The control register for serial I/O interface module, SIOCON, is located at E1H in set 1, bank 0. It has the control
setting for SIO module.
Clock source selection (internal or external) for shift clock
Interrupt enable
Edge selection for shift operation
Clear 3-bit counter and start shift operation
Shift operation (transmit) enable
Mode selection (transmit/receive or receive-only)
Data direction selection (MSB first or LSB first)
A reset clears the SIOCON value to "00H". This configures the corresponding module with an internal clock
source at the SCK, selects receive-only operating mode, and clears the 3-bit counter. The data shift operation
and the interrupt are disabled. The selected data direction is MSB-first.
SIO shift clock selection bit:
0 = Internal clock (P.S Clock)
1 = External clock (SCK)
Data direction control bit:
0 = MSB-first mode
1 = LSB-first mode
Shift clock edge selection bit:
0 = T
X
1 = T
X
14-2

Serial I/O Module Control Register (SIOCON)

MSB
.7
.6
SIO mode selection bit:
0 = Receive only mode
1 = Transmit/receive mode
at falling edges, Rx at rising edges
at rising edges, Rx at falling edges
Figure 14-1. Serial I/O Module Control Register (SIOCON)
S3C8275X/F8275X/C8278X/F8278X/C8274X/F8274X
E1H, Set 1, Bank 0, R/W
.5
.4
.3
.2
SIO shift operation enable bit:
0 = Disable shifter and clock counter
1 = Enable shifter and clock counter
SIO counter clear and shift start bit:
0 = No action
1 = Clear 3-bit counter and start shifting
.1
.0
LSB
SIO interrupt pending bit:
0 = No interrupt pending
0 = Clear pending condition
(when write)
1 = Interrupt is pending
SIO interrupt enable bit:
0 = Disable SIO interrupt
1 = Enable SIO interrupt