HP Integrity rx4610 User Manual page 192

Hp server rx4610 user guide
Hide thumbs Also See for Integrity rx4610:
Table of Contents

Advertisement

Chapter 11
User Notification
The first row that contains the defective DIMM will be mapped out and the
system will continue to boot with the remaining memory. An error message will
be displayed to video for the mapped out defect DIMM.
"First row test"
"0064MB"
"Base memory test" - displayed on the upper LCD line and sometimes
Later an error message for the defective DIMM will be displayed on the video as
follows:
8C9X: "DIMMS mapped out: Upper Board, n-n+3".
Where 'n' refers to the DIMM number.
Example: Consider a system that is populated with two rows of 256 MB DIMMS
in the upper board rows 1-4 and 5-8. If a single bit memory error was detected in
DIMM 5 during the first row memory test and if no errors were found during the
base memory test, the following message will appear on the video during POST:
2048 MB Total Memory Installed
1024 MB Configured
1024 MB Tested
The first line is the total memory installed (regardless of condition). The second
line is the total memory useable (and is less than the first line, only if defective
DIMMS were found). The third line counts the memory as the test is being
performed. When the test is completed, the number in this line should equal the
number in the second line.
The following error message for the defective DIMM 5 will be displayed on the
video as follows:
"8C95: DIMMs mapped out: Lower Board, 5 - 8"
User Action
If the user is satisfied with the configured memory on the system, no action is
required. Otherwise, follow these steps:
184
- displayed on the upper LCD line during first row
test
- displayed on the lower LCD line during first row
test
this message can go by very fast
Troubleshooting

Advertisement

Table of Contents
loading

Table of Contents