the configuration file. The utility automatically programs all SDRs that are not
tagged. The utility also copies all written SDRs to the sdr.tmp file. Because this
file contains an image of what was loaded, it is useful for debugging the server.
Updating the FRU Non-Volatile Storage Area
After the system configuration is determined, a typical configuration file updates
the FRU non-volatile storage area. It will first verify the Common Header area
and checksum from the specified FRU file with what is programmed in the FRU
non-volatile storage device. If specified, the Internal Use Area is then read out of
the specified FRU file and is programmed into the non-volatile storage device.
Then Chassis, Board and Product areas are read out of the specified FRU file and
programmed into the non-volatile storage device. Lastly the Multi-Record Area is
read out of the specified FRU file, and then the area is programmed into the FRU
non-volatile storage device.
Cleaning Up and Exiting
If an update was successfully performed, the utility displays an appropriate
message and then exits with an exit code of 0. On the other hand, if the utility
fails, it immediately exits with an error message and an exit code.