HP Integrity rx4610 User Manual page 123

Hp server rx4610 user guide
Hide thumbs Also See for Integrity rx4610:
Table of Contents

Advertisement

Chapter 10
Updating/Viewing Config Data
The Config menu contains a dynamic list of options that corresponds to the
configuration classes in the current ini file. Each configuration class in the ini
file represents a configuration item, such as EMP or PEP.
When you select an item from the Config menu, the utility reads the configuration
data of that item from the BMC and creates a setup page containing those values.
The setup pages may have drop-down boxes, edit boxes, and/or buttons. Use the
<Tab>, <F5>, or Down arrow keys to move forward, and use <F6> or Up
arrow keys to move backwards between each item.
Press the <Enter> key while on a drop-down box to display the other options
available. Then use the arrow keys to move up or down the list. Press the
<Enter> key to select an item from the drop-down box. Each item in the drop-
down boxes displays a brief description in the tip-view window. Use the <Esc>
key to exit from any level of the configuration to a previous level.
Save the configuration data by selecting the <Save> button and pressing
<Enter>. Use the <Cancel> button or <Esc> key to abort changes and return
to the main window.
Platform Setup
The Platform setup page lets you configure platform-specific features, including
the accelerated cool-down period.
Accelerated Cool Down
This feature lets you enable the system to cool down more rapidly when the
system is powered off. Set the accelerated cool-down timeout in seconds. The
range is 0 to 65535 seconds. If accelerated cool-down is enabled, that is, the cool-
down time is not 0, the BMC leaves the system fans running for the specified time
after the system is powered down.
Configuring the HP Server
115