4.6.6 Scales

Note. The scales configured here are used to scale analog channel data on the Chart View when Advanced configuration
is selected. It has no effect on the Bargraph View (which always uses the engineering range of the analog signal displayed) or on
digital channels.
Scales
<---
Primary range low
Primary range high
Secondary range low
Secondary range high
Scale select source
100.0
0.0
90.0
60.0
None
Set within the range –999 to 9999.
Set within the range –999 to 9999.
See Primary scale range low, above. Can be use to zoom in
or out on data displayed in the Chart View.
See Primary scale range high, above.Can be use to zoom in
or out on data displayed in the Chart View.
Select the digital source used to switch between the primary
and secondary scales.
Secondary
Primary