Mitsubishi Electric MELSEC iQ-F Series User Manual page 76

Hide thumbs Also See for MELSEC iQ-F Series:
Table of Contents

Advertisement

If an error occurs while the automatic detection of connected device is being executed, the window shown below appears.
Each of the error codes listed below fills the last four digits of <0x2c09****>.
Error code
Error details and cause
C055H and C056H
System error
C059H
The function which is not supported by the target device
was executed.
C05CH
• The setting value of the communication setting is out of
• Items of communication setting which cannot be set on
• The required setting items have not been set to the
C061H
System error
CEE0H
The detection or another online function was executed by
another peripheral.
CEE1H to CEE2H
System error
CF10H
CF20H
• The setting value of the communication setting is out of
• Items of communication setting which cannot be set on
• The required setting items have not been set to the
CF30H
The parameter which is not supported by the target
device was specified.
CF31H
System error
CF50H
7 PARAMETER SETTINGS
74
7.3 Basic Setting
range.
the target device are set.
target device.
range.
the target device are set.
target device.
Action
• Check the precautions for the function executed.
• Check the operating status and connection status of the target device.
• Check the connection of the Ethernet cable and the hub.
• Check the line status of Ethernet.
• Reset the CPU module and target device, and execute the function again.
If the above actions do not solve the problem, contact the manufacturer of
the target device.
Check whether the function executed is supported by the target device.
Correct the setting details, and retry the operation.
• Check the precautions for the function executed.
• Check the operating status and connection status of the target device.
• Check the connection of the Ethernet cable and the hub.
• Check the line status of Ethernet.
• Reset the CPU module and target device, and execute the function again.
If the above actions do not solve the problem, contact the manufacturer of
the target device.
Execute the other function after the automatic detection of connected
devices is completed.
• Check the precautions for the function executed.
• Check the operating status and connection status of the target device.
• Check the connection of the Ethernet cable and the hub.
• Check the line status of Ethernet.
• Reset the CPU module and target device, and execute the function again.
If the above actions do not solve the problem, contact the manufacturer of
the target device.
Correct the setting details, and retry the operation.
Check the version of the target device.
• Check the precautions for the function executed.
• Check the operating status and connection status of the target device.
• Check the connection of the Ethernet cable and the hub.
• Check the line status of Ethernet.
• Reset the CPU module and target device, and execute the function again.
If the above actions do not solve the problem, contact the manufacturer of
the target device.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec iq-f fx5-enetFx5-u-enet-e09r736

Table of Contents