Mitsubishi Electric MELSEC iQ-F Series User Manual page 130

Hide thumbs Also See for MELSEC iQ-F Series:
Table of Contents

Advertisement

Event
Event
code
type
309A
System
309B
System
309C
System
309D
System
309E
System
30A8
System
30A9
System
30AA
System
30AB
System
30AC
System
30AD
System
30AE
System
3103
System
3104
System
3106
System
3107
System
3108
System
3109
System
310B
System
310D
System
310F
System
3200
System
3CF1
System
3E30
System
3E31
System
3E32
System
3E33
System
3E34
System
3E35
System
3E36
System
3E37
System
3E38
System
10 TROUBLESHOOTING
128
10.7 List of Event Code
Event
Event
Detected event
category
status
Error
Moderate
The target IP address setting number is outside
the range. (IP filter settings)
Error
Moderate
The excluded IP address number is outside the
range. (IP filter settings)
Error
Moderate
The excluded IP address is outside the range.
(IP filter settings)
Error
Moderate
Target module support error (IP address
settings parameter)
Error
Moderate
Target module support error (Gateway address
setting parameter)
Error
Moderate
The total number of occupied stations is outside
the range. (Configuration setting parameter)
Error
Moderate
The master station and remote station IP
addresses match (Configuration setting
parameter)
Error
Moderate
Simple CPU communication parameter out of
range
Error
Moderate
E-mail setting parameter out of range
Error
Moderate
DNS setting parameter out of range
Error
Moderate
MQTT connection configuration parameter
information is incorrect.
Error
Moderate
Certificate tool setting parameter information is
incorrect.
Error
Moderate
Certificate read failure
Error
Moderate
Certificate read failure
Error
Moderate
Certificate read failure
Error
Moderate
Certificate read failure
Error
Moderate
Certificate read failure
Error
Moderate
Certificate read failure
Error
Moderate
Certificate read failure
Error
Moderate
Client certificate read failure
Error
Moderate
Client certificate read failure
Error
Moderate
Security function error (Encryption
communication)
Error
Major
BINT disconnection detection timeout error
Error
Major
The fixed memory block acquisition/release ID
number is invalid.
Error
Major
Fixed memory block acquisition/release context
error
Error
Major
Error in forced cancellation of waiting for
variable memory block acquisition/release
Error
Major
Error in forced cancellation of waiting due to
reset of fixed memory block acquisition/release
object
Error
Major
Fixed memory block acquisition/release
parameter error
Error
Major
The variable memory block acquisition/release
ID number is invalid.
Error
Major
Variable memory block acquisition/release
context error
Error
Major
Error in forced cancellation of waiting for
variable memory block acquisition/release
Error
Major
Error in forced cancellation of waiting due to
reset of variable memory block acquisition/
release object
Detailed information
Detailed
Detailed
information 1
information 2
Parameter
*2
information
Parameter
*2
information
Parameter
*2
information
Parameter
*2
information
Parameter
*2
information
Parameter
*2
information
Parameter
*2
information
Parameter
*2
information
Parameter
*2
information
Parameter
*2
information
Parameter
*2
information
Parameter
*2
information
Detailed
information 3
Failure
information
Failure
information
Failure
information
Failure
information
Failure
information
Failure
information
Failure
information
Failure
information
Failure
information
Failure
information

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec iq-f fx5-enetFx5-u-enet-e09r736

Table of Contents