Mitsubishi Electric MELSEC iQ-F Series User Manual page 140

Hide thumbs Also See for MELSEC iQ-F Series:
Table of Contents

Advertisement

Buffer memory address
Decimal
Hexadecimal
4398
0112EH
4399
0112FH
4400
01130H
4401
01131H
4402
01132H
4403
01133H
4404
01134H
6400 to 8447
1900H to 20FFH
8500
2134H
8501
2135H
8502 to 8508
2136H to 213CH
8509
213DH
8510
213EH
8520, 8521
2148H, 2149H
8522, 8523
214AH, 214BH
8524
214CH
8525
214DH
8526, 8527
214EH, 214FH
8528, 8529
2150H, 2151H
8530
2152H
8531
2153H
8540 to 8551
215CH to 2167H
8560 to 8571
2170H to 217BH
8580 to 8591
2184H to 218FH
8600, 8601
2198H, 2199H
8602, 8603
219AH, 219BH
8604
219CH
8605
219DH
8606
219EH
8620 to 8626
21ACH to 21B2H
8640 to 8646
21C0H to 21C6H
8660 to 8666
21D4H to 21DAH
8680 to 8686
21E8H to 21EEH
8700 to 8706
21FCH to 2202H
8720 to 8726
2210H to 2216H
8740 to 8746
2224H to 222AH
APPX
138
Appendix 4 Buffer Memory
Name
DNS setting change function
Area for simple CPU communication
BACnet communication device
BACnet communication
Accumulator 1
BACnet communication
Accumulator 2
BACnet communication
Accumulator 3
BACnet communication
Accumulator 4
BACnet communication
AnalogInput 1
BACnet communication
AnalogInput 2
BACnet communication
AnalogInput 3
BACnet communication
AnalogInput 4
BACnet communication
AnalogInput 5
BACnet communication
AnalogInput 6
BACnet communication
AnalogInput 7
BACnet communication
AnalogInput 8
DNS setting storage area write request
DNS setting storage area write status
DNS setting storage area clear request
DNS setting storage area clear status
DNS setting change function enable flag
DNS setting storage area write error
code
DNS setting storage area clear error
code
SystemStatus
Module status
Time setting reception
Time setting read flag
I-Am transmission
Object ID
PresentValue
OutOfService
Reliability
Scale
MaxPresValue
Pulse set value
Units
Same configuration as BACnet
communication Accumulator 1
Same configuration as BACnet
communication Accumulator 1
Same configuration as BACnet
communication Accumulator 1
Object ID
PresentValue
OutOfService
Reliability
Units
Same configuration as BACnet
communication AnalogInput 1
Same configuration as BACnet
communication AnalogInput 1
Same configuration as BACnet
communication AnalogInput 1
Same configuration as BACnet
communication AnalogInput 1
Same configuration as BACnet
communication AnalogInput 1
Same configuration as BACnet
communication AnalogInput 1
Same configuration as BACnet
communication AnalogInput 1
Initial value
Read, write
0
Read, write
0
Read
0
Read, write
0
Read
0
Read
0
Read
0
Read
Read, write
0
Read, write
0
Read
0
Read
0
Read, write
0
Read, write
0
Read
0
Read, write
0
Read, write
0
Read, write
0
Read
0
Read
0
Read, write
0
Read
0
Read
0
Read, write
0
Read, write
0
Read, write
0
Read