Alarm
Alarm
ID
Name
3851
Exhaust
Fan Fault
3852
Ambient
Temperatu
re Low
3853
ESU
Physical
Location
Failure
3856
Battery
Fault
Protection
Issue 08 (2022-11-15)
Severity
Possible Cause
Major
Cause ID = 1–12
The exhaust fan is
faulty.
Major
Cause ID = 1
The ambient
temperature in the
battery cabin is too low.
Cause ID = 2
The ambient
temperature in the
control unit cabin is too
low.
Minor
Cause ID = 1
ESU physical location
failed.
Major
Cause ID = 1
Some battery packs are
severely faulty, causing
the system to shut
down.
Cause ID = 2
The temperature of
some battery packs is
too low. As a result,
charge capacity is not
reached due to low
temperature protection.
Copyright © Huawei Technologies Co., Ltd.
10 Alarm Reference
Suggestion
1. Check whether the cable to the
exhaust fan is loose. If yes,
reconnect the cable. Check whether
the fan is damaged or burnt. If yes,
replace the fan.
2. Check whether the TCU
connected to the exhaust fan works
properly.
3. If the fault persists, contact your
technical support.
1. Check whether the air
conditioners in the battery cabin
are faulty.
2. Check whether the doors of the
battery cabin are completely closed.
1. Check whether the air
conditioners in the control unit
cabin are faulty.
2. Check whether the doors of the
control unit cabin are completely
closed.
1. Check whether the network
connections between the ESCs are
normal.
2. Check whether the network
connections between the CMU and
the first and last nodes of the ESC
are normal.
3. Check whether the RS485 cable
between ESC-1 and the CMU is
properly connected.
Maintain the battery pack based on
the alarm and troubleshooting
suggestions.