Appendix 1.10 Grounding Plate And Clamp Fitting Outline Drawings - Mitsubishi Electric MELDASMAGIC64 Connection Manual

Hide thumbs Also See for MELDASMAGIC64:
Table of Contents

Advertisement

Appendix 1.10 Grounding Plate and Clamp Fitting Outline Drawings

Appendix 1.10 Grounding Plate and Clamp Fitting Outline Drawings
The shield wire generally only needs to be
grounded to the connector's case frame.
However, the effect can be improved by
directly grounding to the grounding plate as
shown on the right.
Install the grounding plate near each unit.
Peel part of the cable sheath as shown on
the right to expose the shield sheath. Press
that section against the grounding plate
with the clamp fitting. Note that if the cable
is thin, several can be clamped together.
Install the grounding plate directly onto the
cabinet or connect a grounding wire so that
sufficient frame grounding is achieved.
If the AERSBAN- SET, containing the
grounding plate and clamp fitting, is
required, please contact Mitsubishi.
• Outline drawing
Grounding plate
outline drawing
Note 1 M4 screw
Note 1) Screw hole for wiring to cabinet's grounding plate
Note 2) The grounding plate thickness is 1.6mm
AERSBAN-DSET
AERSBAN-ESET
(Note) a, b and c in the table are symbols in the outline drawing of
the grounding plate.
Appendix 1 Outline Drawings
17.5
2-
5 hole
Ø
Installation hole
6
22
35
a
b
c
100
86
30
Two clamp fittings A
70
56
One clamp fitting B
Clamp fitting
(Fitting A,B)
Clamp section drawing
Presser outline drawing
Clamp metal fitting outline drawing
Enclosed fittings
79
Cable
Presser
Grounding
plate
Shield sheath
24
0
-0.2
29
10
MAX L
Clamp fitting A
Clamp fitting B
(Note) L in the table is a
symbol in the
outline drawing
of the clamp
metal fittings.
L
70
45

Advertisement