Installation; General Specifications - Mitsubishi Electric MELDASMAGIC64 Connection Manual

Hide thumbs Also See for MELDASMAGIC64:
Table of Contents

Advertisement

3. Installation

3.1 General Specifications

NC Card peripheral environment conditions
Type name
Unit name
Ambient
temperature
Ambient
humidity
Working atmosphere
Power voltage
Current
consumption
Power drop characteristics
Heating value
Unit size
(*1)
If these characteristics are not satisfied, the NC Card cannot back up the absolute position information of
the machine position when the power is turned OFF.
(*2)
Excluding spacers
Environmental conditions in electric cabinet
Type name
Unit name
Ambient
temperature
Ambient
humidity
Vibration resistance
Shock resistance
Working atmosphere
Power voltage
Current consumption
Heating value
Mass
Unit size
(*3)
When all DO points are ON
3. Installation
3.1 General Specifications
HR621/HR623
During operation
During storage
During operation
During storage
3.3V
5V
12V
24V
248.9×107.6×20 (mm)
FCU6-DX210, FCU6-DX211
During operation
During storage
During operation
During storage
5V 1A (max), 24V 3.6A (max) (*3)
FCU6-HR655
NC Card
-20~60°C
40~75% RH (with no dew condensation)
40~75% RH (with no dew condensation)
No corrosive gas or dust
3.3VDC ± 5%
5VDC ± 2%
12VDC ± 2%
0.2A (max)
2.5A (max)
0.5A (max)
0.7A (max)
Personal computer 5V: 4.5V
→4.0V is 1ms or more (*1)
19W
174.63×106.68×21
Base I/O unit
-20~60°C
45~75% RH (with no dew condensation)
45~80% RH (with no dew condensation)
2
4.9m/s
or less (during operation)
2
29.4m/s
or less (during operation)
No corrosive gas or dust
24VDC ± 5%
Ripple ± 5% (P-P)
90W (*3)
220×168×35 (mm)
5
HR682
Relay card
0~55°C
24VDC ± 5%
Ripple ± 5% (P-P)
0.5A (max)
22W
115×156×30 (mm) (*2)
(mm)
FCU6-DX220, FCU6-DX221
0~55°C
5V 1A (max), 24V 4.8A (max) (*3)
110W (*3)
2.0kg
12W

Advertisement