F021 Cable (Manual Pulse Generator); Appendix - Mitsubishi Electric MELDASMAGIC64 Connection Manual

Hide thumbs Also See for MELDASMAGIC64:
Table of Contents

Advertisement

Cable type name: F021 cable
Application: Relay card – Manual pulse generator connection
(when two manual pulse generators are connected)
Assembly drawing
Relay card side
(1)(2)(3)
Connection diagram
Relay card side
1HA
1HB
+12V
GND
2HA
2HB
+12V
GND
Manufacturing precautions
(1) The wire material shall be a shielded, 4-pair stranded cable equivalent to AWG22 (0.3mm
(2) The parts used shall be Mitsubishi recommended parts. Equivalent parts may be used
providing they are compatible with the specifications.
(3) Attach the nameplate with protective cover stamped with the cable name in the position
designated in the assembly drawing.
(4) Fold the wire material shield on the relay card side over the sheath, and wrap copper foil tape
over it. Connect the copper foil tape wrapped around the sheath to a connector GND plate.
(5) Stamp the name of each signal on the crimp terminal side mark tube and install.
Appendix 2 Cable Manufacturing Drawings

2.13 F021 Cable (Manual pulse generator)

(4)
Manual pulse generator side
F021
F021
F021
(5)
1
2
10
9
3
4
12
11
Case frame
FG
List of parts used
No. Part name
1
Connector
2
Contact
Connector
3
case
Wire
4
material
Crimp
5
terminal
Maximum cable length: 50m
Manual pulse generator side
1ch
2ch
94

Appendix 2.13

Recommended part type Qty
Hirose Electric
CDA-15P
Hirose Electric
CD-PC-111
Hirose Electric
HAD-CTH
Sumitomo Electric
B-22 (19) U × 2SJ-1 × 9
J.S.T. Mfg
V1.25-3
2
).
1
8
1
(4)
8

Advertisement

Table of Contents
loading

Table of Contents