Appendix 2.3 R031 Cable (Analog Signal Input/Output) - Mitsubishi Electric MELDASMAGIC64 Connection Manual

Hide thumbs Also See for MELDASMAGIC64:
Table of Contents

Advertisement

Cable type name: R031 cable
Application: Analog signal input/output
Assembly drawing
Remote I/O unit side
(1)(2)
Connection diagram
Remote I/O unit side
Manufacturing precautions
(1) The wire material shall be a shielded, 6-pair stranded cable equivalent to UL1061-2464
Standard AWG22 (0.3mm
(2) The parts used shall be Mitsubishi recommended parts. Equivalent parts may be used
providing they are compatible with the specifications.
(3) Attach the nameplate with protective cover stamped with the cable name in the position
designated in the assembly drawing.
(4) Fold the wire material shield on the remote I/O unit side over the sheath, and wrap copper foil
tape over it. Connect the copper foil tape wrapped around the sheath to a connector GND
plate.
(5) Stamp the name of each signal on the crimp terminal side mark tube and install.
(6) Insulate the crimp terminals of unused signal wires with vinyl tape, etc.
(7) Part 1 (plug) is usually used for wire material of AWG 24 (0.2mm
specifications, but AWG 22 (0.3mm
Appendix 2 Cable Manufacturing Drawings
2.3 R031 Cable (Analog signal input/output)
Analog input/output signal
(4)
(3)
R031
R031
2
1
12
11
3
5
13
15
7
Case frame
FG
2
).
2
) can also be used.
Option (compatible connector set)
FCUA-CS000
(Note that this is only compatible with the
remote I/O unit side.)
List of parts used
No. Part name
1
Plug
2
Shell
Wire
3
material
Crimp
4
terminal
Analog input/output signal
AI0
GND
AI1
GND
AI2
GND
AI3
GND
AO
GND
84
Appendix 2.3
Recommended part type Qty
Sumitomo 3M
10120-3000VE
Sumitomo 3M
10320-52F0-008
UL1061-2464
AWG22 × 6P
J.S.T. Mfg
V1.25-4
Maximum cable length: 30m
2
) or less in the catalog
1
1
(1)
10

Advertisement

Table of Contents
loading

Table of Contents