7.2 Names of Each Remote I/O Unit Section

FCUA-DX10* FCUA-DX11*/FCUA-DX12*
Front view
(1)
(2)
(3)
(4)
(Front)
(5)
Bottom
(6)
view
(7)
(Rear)
(1) DI-L (machine input signal connector)
(2) DS (transfer speed changeover switch)
(3) CS (channel No. changeover switch)
(4) DO-L (machine output signal connector)
(5) RIO1 (serial connection connector #1)
(6) RIO2 (serial connection connector #2)
(7) DCIN (+24VDC power input connector)
(8) DI-R (machine input signal connector)
(9) DO-R (machine output signal connector)
(10) HANDLE (manual pulse generator signal
input connector)
(11) AIO (analog signal input/output connector)
7. Remote I/O Unit Connection (FCUA-DX1**)
7.2 Names of Each Remote I/O Unit Section
Front view
(8)
(1)
(2)
(3)
(3)
(4)
(9)
(Front)
(5)
Bottom
(6)
view
(7)
(Rear)
FCUA-DX13*
Front view
(10)
(1)
(2)
(3)
(3)
(4)
(Front)
(5)
Bottom
(6)
view
(7)
(Rear)
DS
4
CS
Enlarged drawing of DS and CS
(Note) Baud rate changeover
52
FCUA-DX14*
Front view
(1)
(2)
(3)
(4)
(Front)
(5)
Bottom
(6)
view
(7)
(Rear)
For changeover of transfer speed.
Normally set to left side.
Not used
Selection of channel No.
Left side : 2.8Mbps
Right side : 1.4Mbps
(11)
(3)

Advertisement

Table of Contents
loading

Table of Contents