Appendix 3 Parts for EMC Measures

Appendix 3.1 Shield Clamp Fitting

The effect can be increased by directly connecting the cable's shield sheath to the grounding plate.
Install the grounding plate near the outlet (within 10cm) of each panel, and press against the grounding
plate with the clamp fitting. If the cables are thin, several can be bundled and clamped together.
To provide sufficient frame grounding, install the grounding plate directly on the cabinet or connect with
a grounding wire.
If the AERSBAN- SET, containing the grounding plate and clamp fitting, is required, please contact
Mitsubishi.
Outline drawing
Grounding plate
Installation hole
Note 1
M4 screw
Note 1) Screw hole for wiring to cabinet's grounding plate
Note 2) The grounding plate thickness is 1.6mm
AERSBAN-DSET
AERSBAN-ESET
Appendix 3 Parts for EMC Measures
Appendix 3.1 Shield Clamp Fitting
Clamp fitting
(Fitting A, B)
Clamp section drawing
17.5
2-φ5 hole
22
6
35
A
B
C
(mm)
(mm)
(mm)
100
86
30
70
56
Peel the cable sheath
at the clamp section
Grounding plate
Clamp fitting
Enclosed fitting
Two clamp fittings A
One clamp fitting B
102
Cable
Cable
Shield sheath
10
MAX L
Unit: mm
Clamp fitting A
Clamp fitting B
L (mm)
70
45