5.5.3 CF31, CF32 Input Circuit

Refer to "7.4 Outline of Digital Signal Input Circuit" for the base I/O unit CF31 and CF32 input circuits.
1
Unit name
2
Card name
3
Input type
4
COM pin connection +24V/GND
5
No. of input points
6
Pin used for input

5.5.4 CF33, CF34 Output Circuit

Refer to "7.5 Outline of Digital Signal Output Circuit" for the base I/O unit CF33 and CF34 output
circuits.
1
Unit name
2
Card name
3
Output type
4
Output current
5
No. of output points
6
Pin used for output

5.5.5 Specifications of ADD ON PCB Connected to CR31

Refer to "7. Remote I/O Unit Connection" for add-on PCB specifications. One add-on PCB can be
installed on the base I/O unit, and it occupies one station. Reference items are as in the following table.
Name
1
RX323-1
2
RX323
3
RX324-1
4
RX324
5
RX331
6
RX341
Refer to "7.6 Outline of Analog Signal Output Circuit" for the analog output specifications.
Refer to "7.7 Outline of Analog Signal Input Circuit" for the analog input specifications.
5. Base I/O Unit Connection
5.5 Base I/O Unit Input/Output Specifications
FCU6-DX210
HR325
Sink/source
48 points
X00~X2F
FCU6-DX210
HR325
Sink type
60mA/point
48 points
Y00~Y2F
Reference item
7.9
Connection of FCUA-DX11* unit and
machine control signal
7.10 Connection of FCUA-DX12* unit and
machine control signal
7.9
Connection of FCUA-DX11* unit and
machine control signal
7.10 Connection of FCUA-DX12* unit and
machine control signal
7.11 Connection of FCUA-DX13* unit and
handle
7.13 Connection of FCUA-DX14* unit and
analog input/output signal
FCU6-DX211
FCU6-DX220
HR335
HR327
Sink/source
Sink/source
+24V/GND
+24V/GND
48 points
64 points
X00~X2F
X00~X3F
FCU6-DX211
FCU6-DX220
HR335
HR327
Source type
Sink type
60mA/point
60mA/point
48 points
64 points
Y00~Y2F
Y00~Y3F
39
FCU6-DX221
HR337
Sink/source
+24V/GND
64 points
X00~X3F
FCU6-DX221
HR337
Source type
60mA/point
64 points
Y00~Y3F
Reference connector name
FCUA-DX110: DI-R, DO-R
FCUA-DX120: DI-R, DO-R
FCUA-DX111: DI-R, DO-R
FCUA-DX121: DI-R, DO-R
FCUA-DX13*: HANDLE
FCUA-DX14*: AIO