Cable type name: R041 cable
Application: Remote I/O unit – Manual pulse generator connection
(when one manual pulse generator is connected)
Assembly drawing
Remote I/O unit side
(1)(2)
Connection diagram
Remote I/O unit side
1
11
4
14
5
15
6
16
Case frame
FG
Manufacturing precautions
(1) The wire material shall be a shielded, 6-pair stranded cable equivalent to UL1061-2464
Standard AWG22 (0.3mm
(2) The parts used shall be Mitsubishi recommended parts. Equivalent parts may be used
providing they are compatible with the specifications.
(3) Attach the nameplate with protective cover stamped with the cable name in the position
designated in the assembly drawing.
(4) Fold the wire material shield on the remote I/O unit side over the sheath, and wrap copper foil
tape over it. Connect the copper foil tape wrapped around the sheath to a connector GND
plate.
(5) Stamp the name of each signal on the crimp terminal side mark tube and install.
(6) Part 1 (plug) is usually used for wire material of AWG 24 (0.2mm
specifications, but AWG 22 (0.3mm
Appendix 2 Cable Manufacturing Drawings
2.4 R041 Cable (Manual pulse generator)
Manual pulse generator side
(4)
(3)
R041
R041
2
).
2
) can also be used.
Option (compatible connector set)
FCUA-CS000
(Note that this is only compatible with the
remote I/O unit side.)
List of parts used
No. Part name
1
Plug
2
Shell
Wire
3
material
Crimp
4
terminal
Maximum cable length: 30m
Manual pulse generator side
GND
HA1
HB1
GND
+12V
85
Appendix 2.4
Recommended part type Qty
Sumitomo 3M
10120-3000VE
Sumitomo 3M
10320-52F0-008
UL1061-2464
AWG22 × 6P
J.S.T. Mfg
V1.25-4
2
) or less in the catalog
1
1
(1)
5

Advertisement