27 Troubleshooting
E501
Cause:
The laser stop input is open.
Remedy:
Connect the LASER STOP IN inputs on the TERMINAL connector.
Check the status of the safeguards connected to the LASER STOP
IN inputs.
Check the operation logic of the connected device.
Connect the internal or external power supply to IN COM. 1 (X2) and
OUT COM.1 (Y2) on the TERMINAL connector.
E502
Cause:
The "Stop laser" button in Laser Marker NAVI smart was selected.
Remedy:
Solve the safety problem. Then select "Reset" in the error dialog in Laser
Marker NAVI smart to finish the laser stop status.
E503
Cause:
The remote interlock input is open.
Remedy:
Connect the REMOTE INTERLOCK IN input on the TERMINAL
connector.
Check the status of the safeguards connected to the REMOTE
INTERLOCK IN input.
Check the operation logic of the connected device.
If you want to deactivate this alarm when the shutter is closed, set
"Deactivate while shutter closed" in "System settings" > "Operation/
information" > "INTERLOCK alarm detection".
Connect the internal or external power supply to IN COM. 1 (X2) and
OUT COM.1 (Y2) on the TERMINAL connector.
Applies to LP-RC, LP-RF, LP-RV only.
E505–E509
Cause:
A safety function (e.g. interlock or laser stop) was activated during
marking trigger preparation (data transfer to the laser head).
Remedy:
Reset the alarm if laser radiation was stopped by a laser stop signal,
an interlock signal or the "Stop laser" button in "Laser Marker NAVI
smart".
Check if the signal lines are affected by noise.