Panasonic LP-GS Series Operation Manual page 326

Laser marker navi smart
Hide thumbs Also See for LP-GS Series:
Table of Contents

Advertisement

27 Troubleshooting
E286
Cause:
Marking data are too detailed for the scan speed configured.
Remedy:
Decrease the scan speed.
Applies to LP-GS, LP-RC only.
E287
Cause:
An error occurred in the galvano scanner.
The signal cable or unit power cable is not connected correctly.
Remedy:
Check the power supply.
Check if the AC power line is affected by noise.
Check the connection of cables and signal lines, and restart the laser
marking system.
E290–E292
Cause:
An error occurred in the z-axis adjustment module.
Remedy:
Check the connection of cables and signal lines, and restart the laser
marking system.
Applies to LP-GS only.
E300–E380
Cause:
A system error occurred.
Remedy:
Check the connection of cables and signal lines, and restart the laser
marking system.
326
ME-NAVIS2-OP-1

Hide quick links: