E400
Cause:
Interlock input 1 is open.
Remedy:
Connect the INTERLOCK 1 inputs on the TERMINAL connector.
Check the status of the safeguards connected to the interlock
terminals.
Check the operation logic of the connected device.
If you want to deactivate this alarm when the shutter is closed, set
"Deactivate while shutter closed" in "System settings" > "Operation/
information" > "INTERLOCK alarm detection".
LP-RC, LP-RF, LP-RV: If the error persists even if the interlock
terminals are connected properly, replace the INTERLOCK contactor.
For details, refer to the "Setup and Maintenance Guide".
E401
Cause:
Interlock input 2 is open.
Remedy:
Connect the INTERLOCK 2 inputs on the TERMINAL connector.
Check the status of the safeguards connected to the interlock
terminals.
Check the operation logic of the connected device.
If you want to deactivate this alarm when the shutter is closed, set
"Deactivate while shutter closed" in "System settings" > "Operation/
information" > "INTERLOCK alarm detection".
LP-RC, LP-RF, LP-RV: If the error persists even if the interlock
terminals are connected properly, replace the INTERLOCK contactor.
For details, refer to the "Setup and Maintenance Guide".
E402, E403
Cause:
The laser stop input is open.
Remedy:
Connect the LASER STOP IN inputs on the TERMINAL connector.
Check the status of the safeguards connected to the LASER STOP
IN inputs.
Check the operation logic of the connected device.
Connect the internal or external power supply to IN COM. 1 (X2) and
OUT COM.1 (Y2) on the TERMINAL connector.