The setting range of the laser pulse cycle varies depending on the specified value of the
pulse duration. If you change the pulse duration, adjust the laser pulse cycle.
"Pulse cycle [μs]" (LP-RF, LP-RV):
Specify the time from beginning of one pulse to the next pulse.
A longer pulse cycle and a high scan speed will generate a dotted line.
‒ LP-RF: If you specify a long pulse cycle, the pulse energy increases. A short pulse
‒ LP-RV: The setting range and optimal value of the pulse cycle depends on the value
Related topics
Perform test marking

Fine-tune the laser settings

22.2
Fine-tune the laser settings
To achieve an optimal marking quality, specify more laser setting parameters under "Fine
adjustment".
Go to the "Marking settings" screen and select "Laser settings".
Specify any of the following parameters:
ME-NAVIS2-OP-1
cycle setting results in a low pulse energy.
Setting range: 5.0 to 50.0μs
of the pulse duration.
Pulse duration
Setting range
1ns
0.5 to 5.0μs
4ns
0.5 to 16.6μs
8ns
0.5 to 33.3μs
16ns
0.7 to 62.5μs
30ns
1.2 to 111.1μs
120ns
3.0 to 333.3μs
200ns
5.0 to 500.0μs
The optimal value of the pulse cycle yields the largest average laser power and the
largest pulse energy at the selected pulse duration.
If you specify a pulse cycle that is longer than the optimal value, the average laser
power decreases. A pulse cycle setting that is shorter than the optimal value results
in a lower pulse energy.
(page 52)
(page 231)
22 Laser settings
Pulse cycle
Optimal value
0.5μs
1.6μs
3.3μs
6.2μs
11.3μs
29.4μs