Display all configured channel indicators for the process group currently selected for
display.
Display all configured channel indicators for all process groups.
Note. Selecting this option enables up to 36 channels to be displayed if all 36 channels
are configured.
Stop and start individual totalizers.
Channel totalizers that have not been enabled in the Configuration level are greyed-out.
Note.
When a totalizer is not running (i.e. 'Stop' is selected), the corresponding totalizer
value is shown in red.
When 'Show All Configured Channels' is selected above, this menu changes to
show Group followed by Channel followed by Totalizer.
Reset the totalizer value to the totalizer preset value.
Channel totalizers that have not been enabled in the Configuration level are greyed-out.
Note. When 'Show All Configured Channels' is selected above, this menu changes to
show Group followed by Channel followed by Totalizer.
To acknowledge a particular alarm, use the
and press the
key.
Note.
Active unacknowledged alarms in the current process group are identified by a red
border around the value in the associated channel indicator, alternating with a red
Alarm Event icon in the bottom left hand corner of the same indicator. Active
acknowledged alarms are identified by a continuous red Alarm Event icon in the
bottom left hand corner of the indicator – see Fig. 4.7, page 24.
When 'Show All Configured Channels' is selected above, this menu changes to
show Group followed by Channel.
To acknowledge all active alarms in the current process group simultaneously, select 'All'
and press the
key.
Note. If an alarm in another process group is active, the Global Alarm status icon (
continues to be displayed in the status bar. If an active alarm in another process group is
unacknowledged, the icon is surrounded by a red flashing border (
The short channel tags of individual alarms that have not been configured are greyed-out
in the menu.
Select 'AutoView Scroll' to display the enabled digital indicator for each configured
process group in turn for 40 seconds. The AutoView Scroll status icon (
in the status bar when AutoView Scroll is active. Press any key to cancel AutoView Scroll.
4 Operation
and
keys to highlight it in the menu
).
) is displayed
)
27