Input label
Setting details
FB_EN
Connects with a device used as a recording trigger.
On: The FB is activated (a recording event is executed).
Off: The FB is stopped.
iw_ConnectionNo
Sets the connection number.
is_UserName
Sets the user name registered in the network camera.
is_PassWord
Sets the password registered in the network camera.
iw_VIPortNo
Specifies the port number of the virtual input for the recording event registered in the network
camera.
Output label
Setting details
FB_ENO
On: The execution command is on.
Off: The execution command is off.
FB_OK
The on state indicates that the virtual input port status on the network camera side has been switched.
FB_ERROR
The on state indicates that an error has occurred in the FB.
ERROR_ID
Returns the error code of an error occurred in the FB.
• Do not start the second video recording until the post-trigger recording period (Postbuffer) ends.
• If recording events occur consecutively in a brief period of time and the recording duration of one event
overlaps the recording duration of the subsequent event, this FB may not be completed successfully and a
timeout error (C1E2H) may occur. Ensure that the recording durations of events do not overlap when this
FB is executed.
Setting example
1
"root"
"Pass1234"
9