10.3

M+CPU-CamRec_AXIS_VIControl

Overview

This FB enables or disables the execution trigger of the recording event set to the network camera manufactured by Axis
Communications that is connected to the MELSEC-Q series QnUDVCPU.
M+CPU-CameraRecord_AXIS_VirtualInputControl
(1)
B:FB_EN
(2)
W:iw_ConnectionNo
(3)
S:is_Username
(4)
S:is_Password
(5)
W:iw_VIPortNo
(6)
B:ib_VIPortState
To use this FB, setting labels for subroutine FBs is required. ( Page 54 Creating a program)

Labels

Input labels
No.
Variable name
(1)
FB_EN
(2)
iw_ConnectionNo
(3)
is_UserName
(4)
is_PassWord
(5)
iw_VIPortNo
(6)
ib_VIPortState
Output label
No.
Variable name
(7)
FB_ENO
(8)
FB_OK
(9)
FB_ERROR
(10)
ERROR_ID
10 FB LIBRARY DETAILS (FOR MELSEC-Q SERIES CPU MODULES)
102
10.3 M+CPU-CamRec_AXIS_VIControl
FB_ENO:B
FB_OK:B
FB_ERROR:B
ERROR_ID:W
Name
Data type
Execution command
Bit
Connection number
Word [signed]
User name
String (15)
Password
String (65)
Virtual input port
Word [signed]
number
Virtual input port
Bit
status
Name
Data type
Execution status
Bit
When the FB
Bit
completed
successfully
When the FB
Bit
completed with an
error
Error code
Word [signed]
(7)
(8)
(9)
(10)
Effective
Description
range
On or off
On: The FB is activated.
Off: The FB is not activated.
1 to 16
Specifies the connection number.
4 to 14
Specifies the user name registered in the corresponding
characters
network camera.
(Available strings: a to z, A to Z, 0 to 9)
4 to 64
Specifies the password registered in the corresponding
characters
network camera.
1 to 32
Specifies the port number of the virtual input to be enabled/
disabled.
Page 22 Recording Event Settings
On or off
On: The virtual input port status is enabled.
Off: The virtual input port status is disabled.
Initial value
Description
Off
On: The execution command is on.
Off: The execution command is off.
Off
The on state indicates that sending the command for
switching the virtual input port has been completed.
Off
The on state indicates that an error has occurred in the FB.
0
Returns the error code of an error occurred in the FB.