Mitsubishi Electric MELSEC iQ-R Series User Manual page 31

Camera recording package
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

External device configuration
Set the network camera to be connected.
[Navigation window]  [Parameter]  Programmable controller  [Module Parameter]  [Basic Settings]  [External
Device Configuration]
1.
From "Module List", select "Active Connection Module" and drag and drop it to "List of devices" or "Device map area".
2.
For the selected "Active Connection Module", configure the following.
• Communication Method (Socket Communication)
• Port No. of PLC (1 to 4999, 5010 to 65534)
• IP Address of Sensor/Device (IP address of the network camera)
• Port No. of Sensor/Device (80)
• Existence Confirmation (KeepAlive)
• A PLC port number from 1 to 1023 is used as a reserved port number (WELL KNOWN PORT NUMBERS)
generally, and a number from 61440 to 65534 is used in other communication functions. A number from
1024 to 4999 or 5010 to 61439 is recommended.
• Set 80 to the port number of sensor/device.
3.
Click the [Close with Reflecting the Setting] button and click the [Apply] button in the module parameter.
5 PROGRAMMABLE CONTROLLER SETTINGS
5.1 MELSEC iQ-R Series CPU Module (Built-in Ethernet Port Part)
5
29

Advertisement

Table of Contents
loading

Table of Contents