■Example to create M+CPU-CamRec_AXIS_SetTime (Time setting)
This FB is executed once when the operating status of the CPU module is changed to RUN to set the time information of the
CPU module to the network camera.
■When bSetTime_EN (FB execution command) is turned on, the time of the CPU module is set to the network camera.
• The network camera is specified with iw_ConnectionNo (Connection number).
• The network camera authentication is cleared with is_UserName (User name) and is_PassWord (Password).
• Global label
To use this FB, setting labels for subroutine FBs is required. ( Page 54 Creating a program)
• Program
Input label
Setting details
FB_EN
On: The FB is activated.
Off: The FB is stopped.
iw_ConnectionNo
Sets the connection number.
is_UserName
Sets the user name registered in the network camera.
is_PassWord
Sets the password registered in the network camera.
Output label
Setting details
FB_ENO
On: The execution command is on.
Off: The execution command is off.
FB_OK
The on state indicates that setting the time has been completed.
FB_ERROR
The on state indicates that an error has occurred in the FB.
ERROR_ID
Returns the error code of an error occurred in the FB.
Setting example
1
"root"
"Pass1234"