9. Connect wires and/or electrical connections to the
following electrical components:
A. Glow plug bus (Fig. 31). High temperature shut-
down switch (Fig. 30).
B. Battery, frame, and wire harness ground to the
engine block and the ETR solenoid (Fig. 29).
C. The temperature sender (Fig. 28). The oil low
pressure switch, starter, and alternator (Fig 27).
10.Connect air filter hose to the engine.
11. Connect coolant hoses to the water pump, radiator
cap, and engine block. Make sure radiator drain is shut.
Fill radiator with coolant (see Check Coolant System).
12.Secure yoke flange to the lower fan belt pulley with
three socket head screws and lock washers (Fig. 26).
A. Apply Loctiter thread locker 242 or equivalent to
the threads of the screws.
B. Torque screws from 30 to 35 ft-lb (41 to 47 N-m).
C. Lubricate yoke slip tube (see Lubrication in Chap-
ter 2 - Product Records and Maintenance).
13.Connect both battery cables to the battery (see Bat-
tery Service in Chapter 5 - Electrical system).
14.Close engine hood.
15.Adjust throttle cable (see Adjust Throttle Cable).
16.Bleed fuel system (see Bleed Fuel System).
Reelmaster 5200-D/5400-D
3
1
1. Cable swivel
2. Cable clamp
3. Fuel hoses (separator)
2
1. Cap screws
Page 3 - 21
6
2
Figure 32
4. Fuel hose (fuel tank)
5. Injection pump
6. Fuel pump
1
Figure 33
2. Fan shroud