Cutting Unit Operating Problems (Cont.)
None of the cutting units operate in either direction.
Units are able to raise and lower.
The rear cutting units do not operate in either direction.
Units are able to raise and lower.
None of the cutting units will lower.
None of the cutting units will raise.
Left and right front cutting units will not raise or lower,
but the other cutting units will raise and lower.
The center front cutting unit will not raise or lower, but
the other cutting units will raise and lower.
The rear cutting units will not raise or lower, but the
other cutting units will raise and lower.
The front cutting units do not backlap, but run in the
forward direction instead.
The front cutting units do not backlap, but all cutting
units run in the forward direction.
The rear cutting units do not backlap, but run in the
forward direction instead.
The rear cutting units do not backlap, but all cutting
units run in the forward direction.
Reelmaster 5200-D/5400-D
The seat sensor actuator is lifting off the seat switch.
The seat sensor or circuit wiring is faulty.
The enable/disable switch or circuit wiring is faulty.
The front reels down sensor or circuit wiring is faulty.
Ground circuit wiring to solenoids may be open.
A hydraulic problem exists (see Troubleshooting
section of Chapter 4 - Hydraulic System).
Solenoid S2 or circuit wiring is faulty.
A hydraulic problem exists (see Troubleshooting
section of Chapter 4 - Hydraulic System).
Lower/mow switch on joystick or circuit wiring is faulty.
Solenoid S6 or circuit wiring is faulty.
A hydraulic problem exists (see Troubleshooting
section of Chapter 4 - Hydraulic System).
Raise switch on joystick or circuit wiring is faulty.
Solenoid S7 or circuit wiring is faulty.
A hydraulic problem exists (see Troubleshooting
section of Chapter 4 - Hydraulic System).
Solenoid S3 or circuit wiring is faulty.
A hydraulic problem exists (see Troubleshooting
section of Chapter 4 - Hydraulic System).
Solenoid S4 or circuit wiring is faulty.
A hydraulic problem exists (see Troubleshooting
section of Chapter 4 - Hydraulic System).
Solenoid S5 or circuit wiring is faulty.
A hydraulic problem exists (see Troubleshooting
section of Chapter 4 - Hydraulic System).
Solenoid S8 or circuit wiring is faulty.
A hydraulic problem exists (see Troubleshooting
section of Chapter 4 - Hydraulic System).
The front backlap switch or circuit wiring is faulty.
Solenoid S9 or circuit wiring is faulty.
A hydraulic problem exists (see Troubleshooting
section of Chapter 4 - Hydraulic System).
The rear backlap switch or circuit wiring is faulty.