Reassembly
1. Make sure all parts are clean before reassembly.
2. Coat new O-rings, Uni-rings, rod seal, back-up ring,
and dust seal with with clean hydraulic oil.
A. Install Uni-ring and O-ring to the piston.
B. Install dust seal, O-ring, back-up ring, and dust
seal to the head.
IMPORTANT: Do not clamp vise jaws against the
shaft surface. Protect shaft surface before mount-
ing in a vice.
Reelmaster 5200-D/5400-D
3. Mount shaft securely in a vise by clamping on the cle-
vis of the shaft.
A. Coat shaft with with clean hydraulic oil.
B. Slide head onto the shaft. Install rod seal onto
shaft and into head.