2 to 5 ft–lb
(2.7 to 6.8 N–m)
Loctite 242
30 to 35 ft–lb
(41 to 47 N–m)
23
4
22
7
23
1.
O-ring
2. Plug
3. Cartridge valve (N.O.)
4. Solenoid (20 watt)
5. O-ring
6. Plug
7. Cartridge valve (N.C.)
8. Solenoid (28 watt)
9. Not used
10. O-ring
11. 45_ hydraulic fitting
Note: The ports on the manifold are marked for easy
identification of components (see Hydraulic Schematics
to identify the function of the hydraulic lines and car-
tridge valves at each port location).
Hydraulic System
4
23
3
23
4
2
1
21
20
2
1
S8
18
19
8
12. O-ring
13. Relief valve cartridge (3000 psi)
14. Relief valve cartridge (2000 psi)
15. Manifold body
16. O-ring
17. Plug
18. 90_ hydraulic fitting
19. Cartridge valve (4 way - 2 position)
20. O-ring
21. Plug
22. Cartridge valve (N.C.)
Page 4 - 72
31
4
32
23
7
6
5
S1
S6
S4
S2
S3
S5
S7
S9
16
1
17
Figure 94
24
25
26
27
28
29
30
11
10
12
2
1
2
1
1
15
1
2
23. Solenoid seal
24. Knob
25. Jam nut
26. Indicator plate
27. Detent plate
28. Set screw
29. Locating plate
30. Rotary cartridge valve (flow control)
31. Detent spring
32. Detent ball
Reelmaster 5200-D/5400-D
13
14
2
RIGHT
FRONT

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Reelmaster 5400-d

Table of Contents