Handling And Transport; Supplied Condition; Factory Inspection; Inspection By Customer - Bosch Rexroth IndraDyn A Series Project Planning Manual

Asynchronous motors mad/maf
Table of Contents

Advertisement

Rexroth IndraDyn A
10

Handling and Transport

10.1 Supplied Condition

Factory Inspection

Electrical test
Mechanical test

Inspection by Customer

DOK-MOTOR*-MAD/MAF****-PR03-EN-P
IndraDyn A motors are delivered in wooden crates or in cartons. Packing
units on pallets are secured by retaining straps.
Injuries due to uncontrolled movement of the
retaining straps when cutting!
⇒ Maintain a sufficient distance and carefully cut the
retaining straps.
CAUTION
On delivery from the factory, the motor drive shaft and the connectors
have protective sleeves. Remove the protective sleeves just before
assembly.
All IndraDyn A motors undergo the following inspections, among others,
at the factory:
• High-voltage test according to EN 60034-1 (= VDE 0530-1).
• Insulation resistance according to EN 60204-1/1.92, Section 20.3.
• Ground terminal connection according to EN 60204-1/1.92, Section
20.3.
• Concentricity and position tolerances of shaft end and fastening flange
according to DIN 42955.
• Vibration measurement according to DIN 2373.
Since all IndraDyn A motors undergo a standardized inspection
procedure, high-voltage tests on the customer side are not required.
Motors and components could be damaged if they undergo several high-
voltage tests.
Destruction of motor components by improperly
executed high-voltage test! Invalidation of
warranty!
⇒ Avoid repeated inspections.
CAUTION
⇒ Observe the regulations of EN 60034-1 (= VDE
0530-1).
Handling and Transport